{"id":1383,"date":"2018-11-12T19:44:38","date_gmt":"2018-11-12T19:44:38","guid":{"rendered":"https:\/\/aviantechnologies.a2hosted.com\/aviantech\/?post_type=product&#038;p=1383"},"modified":"2020-05-06T18:13:01","modified_gmt":"2020-05-06T18:13:01","slug":"diffuse-and-regular-reflectance-measurements","status":"publish","type":"product","link":"https:\/\/aviantechnologies.com\/avianmirror\/product\/diffuse-and-regular-reflectance-measurements\/","title":{"rendered":"Diffuse and Regular Reflectance Measurements"},"content":{"rendered":"<div id=\"pl-1383\"  class=\"panel-layout\" >\n<div id=\"pg-1383-0\"  class=\"panel-grid panel-no-style\" >\n<div id=\"pgc-1383-0-0\"  class=\"panel-grid-cell\"  data-weight=\"1\" >\n<div id=\"panel-1383-0-0-0\" class=\"so-panel widget widget_sow-editor panel-first-child\" data-index=\"0\" data-style=\"{&quot;background_image_attachment&quot;:false,&quot;background_display&quot;:&quot;tile&quot;}\" >\n<div class=\"so-widget-sow-editor so-widget-sow-editor-base\">\n<div class=\"siteorigin-widget-tinymce textwidget\">\n<p>Avian Technologies offers measurement services for reflectance of both specular and diffuse materials in the UV-Vis-NIR region of the spectrum.<\/p>\n<p>Our typical measurement equipment includes two Perkin-Elmer Lambda-9\/19 spectrophotometers: the same instruments that are used in many national laboratories for measurement and calibration of artifacts for diffuse reflectance, specular reflectance and transmittance. Depending on the application we also employ a 150 mm integrating sphere accessory (diffuse reflectance, relative near-normal, specular reflectance and color measurements), a 75 mm integrating sphere (UV-Vis-NIR reflectance, diffuse and total transmittance) or the standard collection geometry (normal transmittance).<\/p>\n<p>We can also provide measurements at d:8\u00b0 (specular included) and d:0 degree (specular excluded) geometries, employing Minolta CM-3610d and CM-3630d spectrophotometers, respectively. These instruments are primarily used for the measurement of color of solids such as paint or textiles.<\/p>\n<h4>Services offered:<\/h4>\n<ul>\n<li>Total Hemispherical Reflectance (8\u00b0:d) from 250-2500 nm\n<ul>\n<li>Measurements are traceable to National Research Council, Canada (we can measure to 230 nm, but measurements below 250 nm are not traceable).<\/li>\n<li>Bandpasses from 1 to 5 nm are available.<\/li>\n<\/ul>\n<\/li>\n<li>Relative Specular Reflectance at near normal incidence (8\u00b0).\n<ul>\n<li>Measurements are traceable to National Research Council, Canada<\/li>\n<\/ul>\n<\/li>\n<li>Color measurements at d:8\u00b0 or d:0\u00b0 geometry.<\/li>\n<\/ul>\n<p>Measurement services are performed on materials to determine their reflectance over a particular wavelength range under defined optical conditions. As the materials may be dependent on sample preparation, these cannot be considered \u2018calibrations\u2019, although the measurement techniques used are those outlined for calibrations<a href=\"#calibrationdef\">*<\/a>.<\/p>\n<\/div>\n<\/div>\n<\/div>\n<div id=\"panel-1383-0-0-1\" class=\"so-panel widget widget_sow-editor\" data-index=\"1\" data-style=\"{&quot;background_image_attachment&quot;:false,&quot;background_display&quot;:&quot;tile&quot;}\" >\n<div class=\"so-widget-sow-editor so-widget-sow-editor-base\">\n<div class=\"siteorigin-widget-tinymce textwidget\">\n<h4>Logistics<\/h4>\n<p>All measurements are charged with a fixed setup fee, which includes instrument set up, calibration, verification, and documentation, plus a fee for each set of measurements. Quantity discounts are available. Contact us for pricing information for both standard and custom measurement services.<\/p>\n<p>We pride ourselves in the quick turnaround of highly accurate and traceable measurements, typically within one week of receiving samples.<\/p>\n<p>All data is reported in either 10 or 25 nm increments at 1 nm (UV-Vis) or 5 nm (UV-Vis-NIR) increments. Graphical data is presented. All samples are double or triple scanned and averaged.<\/p>\n<\/div>\n<\/div>\n<\/div>\n<div id=\"panel-1383-0-0-2\" class=\"so-panel widget widget_sow-editor panel-last-child\" data-index=\"2\" data-style=\"{&quot;background_image_attachment&quot;:false,&quot;background_display&quot;:&quot;tile&quot;}\" >\n<div class=\"so-widget-sow-editor so-widget-sow-editor-base\">\n<div class=\"siteorigin-widget-tinymce textwidget\">\n<h4>References<\/h4>\n<p>\u201cNon-Standard Spectroscopic Measurements\u201d A. Springsteen, Spectroscopy Magazine 12(5), 26-30 (1997)<br \/>\n\u201cTechniques for the Measurement of Specular Reflectance\u201d A. Springsteen, Spectroscopy Magazine 12(8), 24-28 (1997)<br \/>\n\u201cStandards for Reflectance Measurements, Parts I and II\u201d A. Springsteen, Spectroscopy Magazine 15(5), 21-27 (2000); 15(6), 22-25 (2000)<\/p>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<div id=\"pg-1383-1\"  class=\"panel-grid panel-has-style\"  data-style=\"{&quot;id&quot;:&quot;calibrationdef&quot;,&quot;background_image_attachment&quot;:false,&quot;background_display&quot;:&quot;tile&quot;,&quot;cell_alignment&quot;:&quot;flex-start&quot;}\"  data-ratio=\"1\"  data-ratio-direction=\"right\" >\n<div id=\"calibrationdef\" class=\"panel-row-style panel-row-style-for-1383-1\" >\n<div id=\"pgc-1383-1-0\"  class=\"panel-grid-cell\"  data-weight=\"1\" >\n<div id=\"panel-1383-1-0-0\" class=\"so-panel widget widget_sow-editor panel-first-child panel-last-child\" data-index=\"3\" data-style=\"{&quot;background_image_attachment&quot;:false,&quot;background_display&quot;:&quot;tile&quot;}\" >\n<div class=\"so-widget-sow-editor so-widget-sow-editor-base\">\n<div class=\"siteorigin-widget-tinymce textwidget\">\n<p>*Calibration is defined as the measurement and certification of \u2018artifacts\u2019 to be used as secondary standards. Artifacts include tiles and other stable reflectance materials such as Fluorilon&#x2122;-99W, and other \u2018artifact\u2019 quality materials.<\/p>\n<p>Most measurements are traceable to another artifact standard, but the techniques of measurement are traceable to <a href=\"http:\/\/nvlpubs.nist.gov\/nistpubs\/Legacy\/SP\/nistspecialpublication250-46.pdf\" target=\"_blank\" rel=\"noopener noreferrer\">NIST document 250-46<\/a> and\/or <a href=\"https:\/\/www.astm.org\/\" target=\"_blank\" rel=\"noopener noreferrer\">ASTM<\/a> Test Methods, which are listed on the calibration sheets. A &#8216;calibration&#8217; refers to something that is directly traceable to a NIST\/NRC certified primary standard, whereas a measurement is more traceable to a technique\/test method.<\/p>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<style type=\"text\/css\" class=\"panels-style\" data-panels-style-for-post=\"1383\">@import url(https:\/\/aviantechnologies.com\/avianmirror\/wp-content\/plugins\/siteorigin-panels\/css\/front-flex.min.css); #pgc-1383-0-0 , #pgc-1383-1-0 { width:100%;width:calc(100% - ( 0 * 30px ) ) } #pl-1383 #panel-1383-0-0-0 , #pl-1383 #panel-1383-0-0-1 , #pl-1383 #panel-1383-0-0-2 , #pl-1383 #panel-1383-1-0-0 {  } #pg-1383-0 , #pl-1383 .so-panel { margin-bottom:5px } #pl-1383 .so-panel:last-child { margin-bottom:0px } #pg-1383-1.panel-no-style, #pg-1383-1.panel-has-style > .panel-row-style { -webkit-align-items:flex-start;align-items:flex-start } @media (max-width:320px){ #pg-1383-0.panel-no-style, #pg-1383-0.panel-has-style > .panel-row-style , #pg-1383-1.panel-no-style, #pg-1383-1.panel-has-style > .panel-row-style { -webkit-flex-direction:column;-ms-flex-direction:column;flex-direction:column } #pg-1383-0 > .panel-grid-cell , #pg-1383-0 > .panel-row-style > .panel-grid-cell , #pg-1383-1 > .panel-grid-cell , #pg-1383-1 > .panel-row-style > .panel-grid-cell { width:100%;margin-right:0 } #pl-1383 .panel-grid-cell { padding:0 } #pl-1383 .panel-grid .panel-grid-cell-empty { display:none } #pl-1383 .panel-grid .panel-grid-cell-mobile-last { margin-bottom:0px }  } <\/style>\n","protected":false},"excerpt":{"rendered":"<p>Custom measurement services<\/p>\n","protected":false},"featured_media":1717,"template":"","meta":[],"product_brand":[],"product_cat":[89,88],"product_tag":[],"class_list":["post-1383","product","type-product","status-publish","has-post-thumbnail","product_cat-measurement-services","product_cat-services","entry","has-media","first","instock","shipping-taxable","product-type-simple","has-product-nav","col","span_1_of_3","owp-content-center","owp-thumbs-layout-horizontal","owp-btn-normal","owp-tabs-layout-horizontal","has-no-thumbnails"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.1 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Diffuse and Regular Reflectance Measurements - Avian Technologies<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/aviantechnologies.com\/avianmirror\/product\/diffuse-and-regular-reflectance-measurements\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Diffuse and Regular Reflectance Measurements - Avian Technologies\" \/>\n<meta property=\"og:description\" content=\"Custom measurement services\" \/>\n<meta property=\"og:url\" content=\"https:\/\/aviantechnologies.com\/avianmirror\/product\/diffuse-and-regular-reflectance-measurements\/\" \/>\n<meta property=\"og:site_name\" content=\"Avian Technologies\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/aviantechnologiesllc\" \/>\n<meta property=\"article:modified_time\" content=\"2020-05-06T18:13:01+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/aviantechnologies.com\/avianmirror\/wp-content\/uploads\/DiffuseReflectanceMeasurements-square.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"488\" \/>\n\t<meta property=\"og:image:height\" content=\"488\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:site\" content=\"@AvianTechNH\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"2 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/aviantechnologies.com\\\/avianmirror\\\/product\\\/diffuse-and-regular-reflectance-measurements\\\/\",\"url\":\"https:\\\/\\\/aviantechnologies.com\\\/avianmirror\\\/product\\\/diffuse-and-regular-reflectance-measurements\\\/\",\"name\":\"Diffuse and Regular Reflectance Measurements - Avian Technologies\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/aviantechnologies.com\\\/avianmirror\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/aviantechnologies.com\\\/avianmirror\\\/product\\\/diffuse-and-regular-reflectance-measurements\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/aviantechnologies.com\\\/avianmirror\\\/product\\\/diffuse-and-regular-reflectance-measurements\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/aviantechnologies.com\\\/avianmirror\\\/wp-content\\\/uploads\\\/DiffuseReflectanceMeasurements-square.jpg\",\"datePublished\":\"2018-11-12T19:44:38+00:00\",\"dateModified\":\"2020-05-06T18:13:01+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/aviantechnologies.com\\\/avianmirror\\\/product\\\/diffuse-and-regular-reflectance-measurements\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/aviantechnologies.com\\\/avianmirror\\\/product\\\/diffuse-and-regular-reflectance-measurements\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/aviantechnologies.com\\\/avianmirror\\\/product\\\/diffuse-and-regular-reflectance-measurements\\\/#primaryimage\",\"url\":\"https:\\\/\\\/aviantechnologies.com\\\/avianmirror\\\/wp-content\\\/uploads\\\/DiffuseReflectanceMeasurements-square.jpg\",\"contentUrl\":\"https:\\\/\\\/aviantechnologies.com\\\/avianmirror\\\/wp-content\\\/uploads\\\/DiffuseReflectanceMeasurements-square.jpg\",\"width\":488,\"height\":488},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/aviantechnologies.com\\\/avianmirror\\\/product\\\/diffuse-and-regular-reflectance-measurements\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/aviantechnologies.com\\\/avianmirror\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Products &#038; Services\",\"item\":\"https:\\\/\\\/aviantechnologies.com\\\/avianmirror\\\/products\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Diffuse and Regular Reflectance Measurements\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/aviantechnologies.com\\\/avianmirror\\\/#website\",\"url\":\"https:\\\/\\\/aviantechnologies.com\\\/avianmirror\\\/\",\"name\":\"Avian Technologies\",\"description\":\"Solutions for Optical Spectroscopy Materials, Coatings, and Standards\",\"publisher\":{\"@id\":\"https:\\\/\\\/aviantechnologies.com\\\/avianmirror\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/aviantechnologies.com\\\/avianmirror\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/aviantechnologies.com\\\/avianmirror\\\/#organization\",\"name\":\"Avian Technologies LLC\",\"url\":\"https:\\\/\\\/aviantechnologies.com\\\/avianmirror\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/aviantechnologies.com\\\/avianmirror\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/aviantechnologies.com\\\/avianmirror\\\/wp-content\\\/uploads\\\/AT_logo-1.png\",\"contentUrl\":\"https:\\\/\\\/aviantechnologies.com\\\/avianmirror\\\/wp-content\\\/uploads\\\/AT_logo-1.png\",\"width\":1100,\"height\":700,\"caption\":\"Avian Technologies LLC\"},\"image\":{\"@id\":\"https:\\\/\\\/aviantechnologies.com\\\/avianmirror\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.facebook.com\\\/aviantechnologiesllc\",\"https:\\\/\\\/x.com\\\/AvianTechNH\",\"https:\\\/\\\/www.linkedin.com\\\/company\\\/avian-technologies-llc\\\/\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Diffuse and Regular Reflectance Measurements - Avian Technologies","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/aviantechnologies.com\/avianmirror\/product\/diffuse-and-regular-reflectance-measurements\/","og_locale":"en_US","og_type":"article","og_title":"Diffuse and Regular Reflectance Measurements - Avian Technologies","og_description":"Custom measurement services","og_url":"https:\/\/aviantechnologies.com\/avianmirror\/product\/diffuse-and-regular-reflectance-measurements\/","og_site_name":"Avian Technologies","article_publisher":"https:\/\/www.facebook.com\/aviantechnologiesllc","article_modified_time":"2020-05-06T18:13:01+00:00","og_image":[{"width":488,"height":488,"url":"https:\/\/aviantechnologies.com\/avianmirror\/wp-content\/uploads\/DiffuseReflectanceMeasurements-square.jpg","type":"image\/jpeg"}],"twitter_card":"summary_large_image","twitter_site":"@AvianTechNH","twitter_misc":{"Est. reading time":"2 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/aviantechnologies.com\/avianmirror\/product\/diffuse-and-regular-reflectance-measurements\/","url":"https:\/\/aviantechnologies.com\/avianmirror\/product\/diffuse-and-regular-reflectance-measurements\/","name":"Diffuse and Regular Reflectance Measurements - Avian Technologies","isPartOf":{"@id":"https:\/\/aviantechnologies.com\/avianmirror\/#website"},"primaryImageOfPage":{"@id":"https:\/\/aviantechnologies.com\/avianmirror\/product\/diffuse-and-regular-reflectance-measurements\/#primaryimage"},"image":{"@id":"https:\/\/aviantechnologies.com\/avianmirror\/product\/diffuse-and-regular-reflectance-measurements\/#primaryimage"},"thumbnailUrl":"https:\/\/aviantechnologies.com\/avianmirror\/wp-content\/uploads\/DiffuseReflectanceMeasurements-square.jpg","datePublished":"2018-11-12T19:44:38+00:00","dateModified":"2020-05-06T18:13:01+00:00","breadcrumb":{"@id":"https:\/\/aviantechnologies.com\/avianmirror\/product\/diffuse-and-regular-reflectance-measurements\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/aviantechnologies.com\/avianmirror\/product\/diffuse-and-regular-reflectance-measurements\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/aviantechnologies.com\/avianmirror\/product\/diffuse-and-regular-reflectance-measurements\/#primaryimage","url":"https:\/\/aviantechnologies.com\/avianmirror\/wp-content\/uploads\/DiffuseReflectanceMeasurements-square.jpg","contentUrl":"https:\/\/aviantechnologies.com\/avianmirror\/wp-content\/uploads\/DiffuseReflectanceMeasurements-square.jpg","width":488,"height":488},{"@type":"BreadcrumbList","@id":"https:\/\/aviantechnologies.com\/avianmirror\/product\/diffuse-and-regular-reflectance-measurements\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/aviantechnologies.com\/avianmirror\/"},{"@type":"ListItem","position":2,"name":"Products &#038; Services","item":"https:\/\/aviantechnologies.com\/avianmirror\/products\/"},{"@type":"ListItem","position":3,"name":"Diffuse and Regular Reflectance Measurements"}]},{"@type":"WebSite","@id":"https:\/\/aviantechnologies.com\/avianmirror\/#website","url":"https:\/\/aviantechnologies.com\/avianmirror\/","name":"Avian Technologies","description":"Solutions for Optical Spectroscopy Materials, Coatings, and Standards","publisher":{"@id":"https:\/\/aviantechnologies.com\/avianmirror\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/aviantechnologies.com\/avianmirror\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/aviantechnologies.com\/avianmirror\/#organization","name":"Avian Technologies LLC","url":"https:\/\/aviantechnologies.com\/avianmirror\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/aviantechnologies.com\/avianmirror\/#\/schema\/logo\/image\/","url":"https:\/\/aviantechnologies.com\/avianmirror\/wp-content\/uploads\/AT_logo-1.png","contentUrl":"https:\/\/aviantechnologies.com\/avianmirror\/wp-content\/uploads\/AT_logo-1.png","width":1100,"height":700,"caption":"Avian Technologies LLC"},"image":{"@id":"https:\/\/aviantechnologies.com\/avianmirror\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/aviantechnologiesllc","https:\/\/x.com\/AvianTechNH","https:\/\/www.linkedin.com\/company\/avian-technologies-llc\/"]}]}},"_links":{"self":[{"href":"https:\/\/aviantechnologies.com\/avianmirror\/wp-json\/wp\/v2\/product\/1383","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/aviantechnologies.com\/avianmirror\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/aviantechnologies.com\/avianmirror\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/aviantechnologies.com\/avianmirror\/wp-json\/wp\/v2\/media\/1717"}],"wp:attachment":[{"href":"https:\/\/aviantechnologies.com\/avianmirror\/wp-json\/wp\/v2\/media?parent=1383"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/aviantechnologies.com\/avianmirror\/wp-json\/wp\/v2\/product_brand?post=1383"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/aviantechnologies.com\/avianmirror\/wp-json\/wp\/v2\/product_cat?post=1383"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/aviantechnologies.com\/avianmirror\/wp-json\/wp\/v2\/product_tag?post=1383"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}